NCK alarms/ISO alarms
06/2007 Overview of alarms
2-171
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
16694 Channel %1 block %2 following axis/spindle %3 status/instruction %4 is
not possible.
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Status, instruction
Definitions: The stated instruction is not permitted for the current status of the generic coupling.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
16695 Channel %1 block %2 following axis/spindle %3 status/instruction %4 is
not possible.
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Status, instruction
Definitions: The stated instruction is not permitted for the current status of the generic coupling.
Reaction: NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
16696 Channel %1 block %2 following axis/spindle %3 coupling has not been
defined.
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions: An instruction to an undefined coupling is to be executed.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Modify part programm.
Define the coupling and activate, if necessary, before the instruction.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
16697 Channel %1 block %2 following axis/spindle %3 coupling has not been
defined.
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions: An instruction to an undefined coupling is to be executed.
Reaction: NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Modify part programm.
Define the coupling and activate, if necessary, before the instruction.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.