NCK alarms/ISO alarms
06/2007 Overview of alarms
2-135
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
14401 Channel %1 block %2 transformation not available
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The required transformation is not available.
Example:
The following has been programmed: N220 TRACYLI(3) ;Transformation
no. 3-ON
However, only transformation 1 and 2 applies.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department.
Modify part program; program defined transformations only.
Check MD 24100 TRAFO_TYPE_n (assigns the transformation to part program instructions).
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
14403 Channel %1 block %2 preprocessing and main run might not be
synchronized
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Positioning axis curves cannot be predicted reliably. Consequently, the position in the MCS is not
known exactly. It might therefore be possible that a change in the multiple significance of the transfor-
mation has been performed in the main run although no provision was made for this in the preprocess-
ing run.
Reaction: Alarm display.
Remedy: Change part program. Synchronize preprocessing run and main run.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
14404 Channel %1 block %2 illegal parameterization of transformation
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Error has occurred when selecting transformation.
Possible error causes can be:
An axis traversed by the transformation has not been enabled:
Is in spindle mode (-> enable with SPOS)
Is in POSA mode (-> enable with WAITP)
Is concurrent Pos axis (-> enable with WAITP)
Parameterization via machine data has an error.
Axis or geometry axis assignment to the transformation has an error.
Machine data has an error (-> modify machine data, cold restart)
Transformation-dependent error causes can be:
TRANSMIT:
The current machine axis position is unsuitable for selection (e.g. selection in the pole) (-> change
position slightly).
Parameterization via machine data has an error.
Special requirement with respect to the machine axis has not been satisfied (e.g. rotary axis is not a
modulo axis) (-> modify machine data, cold restart).
TRACYL:
The programmed parameter is not allowed when transformation is selected.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department.
Change the part program or change the machine data.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
Komentarze do niniejszej Instrukcji