Profibus alarms
06/2007 Overview of alarms
2-333
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
POSCTRL_CYCLE_DELA especially:
POSCTRL_CYCLE_DELAY must be larger for type 1. POSCTRL_CYCLE_DELAY must be smaller
for type 2.
If alarm-free operation cannot be achieved with any POSCTRL_CYCLE_DELAY setting,
SYSCLOCK_CYCLE_TIME must be increased.
If the error cannot be eliminated by this procedure, please make a note of the error text and contact
the control system manufacturer.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
380020 PROFIBUS DP: bus %3 SDB %4 error %1 source %2
Parameters: %1 = cause of error
%2 = SDB source
Definitions: Error in SDB for PROFIBUS DP configuration.
Error cause:
01=SDB not present in SDB source
02=SDB in SDB source too big.
03=SDB cannot be activated in SDB source.
SDB source:
00=Default SDB1 (selected by MD 11240 = 0 if no user SDB is loaded in the control system)
01=Standard SDB1 (selected by MD 11240 = 1)
02=Standard SDB2(selected by MD 11240 = 2)
...
100 = SDB located in supported memories (SRAM)
101 = User SDB located in file system
102 = SDB reloaded in SRAM during power-up
Reaction: Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check MD 11240
If SDB source = 100: Reload user SDB in passive file system /_N_IBN_DIR/_N_SDB_BIN.
If SDB source = 101, check support accumulators.
If SDB source = 102: Follow the procedure described for troubleshooting alarm 380001.
If alarm 380021 is also signaled, please follow the instructions provided for this alarm.
If the error cannot be eliminated by this procedure, please make a note of the error text and contact
the control system manufacturer.
Program Con-
tinuation:
Switch control OFF - ON.
380021 Profibus-DP: default SDB-Type-2000 was loaded
Definitions: No user-specific SDB exists.
The default SDB was loaded during startup.
Without process peripherals, the NC is ready for a start-up.
The alarm is triggered the first time the NC is switched on or once if the SDB stored in the supported
RAM is lost.
Reaction: Alarm display.
Remedy: Produce user-specific SDB and load in the control or select and activate standard SDB using MD
11240 PROFIBUS_SDB_NUMBER.
Restart the NC.
If the error occurs the next time the NC is switched on, the SDB which was loaded contains an error
and must be created again.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
380022 PROFIBUS DP: configuration of DP master bus %1 has been changed
Parameters: %1 = number of the bus affected
Definitions: The PROFIBUS configuration on the DP master was changed during operation, e.g. by downloading
a new hardware configuration. Since it is possible that the cycle data has changed, operation cannot
be continued and a warm start is required.
Reaction: Channel not ready.
NC Start disable in this channel.