Overview of alarms 06/2007
NCK alarms/ISO alarms
2-20
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
Definitions: An axis identifier is expected for the displayed MD in accordance
with the axis configuration in the AXCONF_MACHAX_USED
and MD 20050 AXCONF_GEOAX_ASSIGN_TAB.
Reaction: NC not ready.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department.
Check axis configuration and enter the missing identifier into the MD or, should the axis not exist,
specify for this channel axis the machine axis 0 in MD 20070 AXCONF_MACHAX_USED. If this con-
cerns a geometry axis that is not to be used (this applies only for 2-axis machining, e.g. on lathes),
then channel axis 0 must be entered additionally in MD 20050 AXCONF_GEOAX_ASSIGN_TAB for
the relevant geometry axis.
Program Con-
tinuation:
Switch control OFF - ON.
4032 Channel %1 wrong identifier for facing axis in %2
Parameters: %1 = channel number
%2 = string: MD identifier
Definitions: According to the axis configuration in MD 20150 GCODE_RESET_VALUES or MD 20100
DIAMETER_AX_DEF, a facing axis identifier is expected at the specified location.
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department.
Add the correct identifier.
Program Con-
tinuation:
Switch control OFF - ON.
4040 Channel %1 axis identifier %2 not consistent with machine data %3
Parameters: %1 = channel number
%2 = string: axis identifier
%3 = string: MD identifier
Definitions: The use of the specified axis identifier in the displayed MD is not consistent the channel's axis config-
uration stated in the MD 20070 AXCONF_MACHAX_USED and MD 20050
AXCONF_GEOAX_ASSIGN_TAB.
Reaction: NC not ready.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department.
Check and correct the identifier used in the MD 10000 AXCONF_
MACHAX_NAME_TAB, MD 20080 AXCONF_CHANAX_NAME_TAB and/or MD 20050
AXCONF_GEOAX_NAME_TAB.
Program Con-
tinuation:
Switch control OFF - ON.