Overview of alarms 06/2007
NCK alarms/ISO alarms
2-170
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
Definitions: The maximum number of master values has been exceeded for the stated type of generic coupling.
Reaction: NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Modify part program, reduce number of master values or use a different type of coupling.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
16690 Channel %1 block %2 following axis/spindle %3 changing the reference
system %4 is not possible.
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Reference system
Definitions: An attempt was made to change the reference system with generic coupling active.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Modify part programm.
End coupling and reactivate with desired reference system.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
16691 Channel %1 block %2 following axis/spindle %3 changing the reference
system %4 is not possible.
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Reference system
Definitions: An attempt was made to change the reference system with generic coupling active.
Reaction: NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Modify part programm.
End coupling and reactivate with desired reference system.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
16692 Channel %1 block %2 following axis/spindle %3 maximum number of
couplings in the block %4 has been exceeded
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Maximum number of couplings
Definitions: The maximum number of generic couplings in the block has been exceeded.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Modify part program.
Reduce the number of generic couplings programmed in the block.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.