NCK alarms/ISO alarms
06/2007 Overview of alarms
2-65
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
10731 Channel %1 block %3 axis %2 working area limitation %4
Parameters: %1 = channel number
%2 = axis name, spindle number
%3 = block number, label
%4 = string (+ or -)
Definitions: For the axis, the planned motion violates the working area limit. The alarm is activated during the prep-
aration of approach or rest blocks at REPOS.
Reaction: Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy: Abort part program with reset.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
10732 Channel %1 block %5 axis %2 working area limitation violated, residual
distance: %6 %3<ALUN>
Parameters: %1 = Channel number
%2 = Axis name, spindle number
%3 = Unit of distance
%4 = Block number, label|residual distance
Definitions: This alarm is generated if it is determined during block preparation that the programmed path of the
stated axis violates the working area limitation.
This alarm is issued instead of alarm 10730 if bit 11=1 in machine data
$MN_ENABLE_ALARM_MASK. Alarm 10732 offers an expanded diagnostics option for the working
area limitation violation. The condition for activation is the presence of the ALUN* alarm file in the HMI.
Reaction: Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy: a) Check NC program for correct positional data and, if necessary, make corrections.
b) Check zero offsets (current frame)
c) Correct working area limitation via G25/G26, or
d) Correct working area limitation via setting data, or
e) Deactivate working area limitation via setting data 43410 WORKAREA_MINUS_ENABLE=FALSE
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
10733 Channel %1 block %5 axis %2 working area limitation violated, residual
distance: %6 %3<ALUN>
Parameters: %1 = Channel number
%2 = Axis name, spindle number
%3 = Unit of distance
%4 = Block number, label|residual distance
Definitions: The motion planned for the axis violates the currently active working area limitation.
The alarm is activated during the preparation of approach or rest blocks for REPOS.
This alarm is issued instead of alarm 10731 if bit11=1 in machine data
$MN_ENABLE_ALARM_MASK. Alarm 10733 offers an expanded diagnostics option for the working
area limitation violation. The condition for activation is the presence of the ALUN* alarm file in the HMI.
Reaction: Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy: Determine the cause of the offset from the initial or target position. The REPOS command is executed
at the end of an ASUB or system ASUB. See also cross reference from ASUBs.
Check the currently active work offset via the current frame.
Also check the external work offsets, overlaid movements ($AA_OFF), DRF and transformation com-
ponents.
Cancel NC program with NC reset.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program