Siemens SINUMERIK 802D sl Dokumentacja Strona 339

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 392
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 338
PLC alarms
06/2007 Overview of alarms
2-339
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
400008 Programming tool - version is not compatible [Version]
Definitions: This version is not compatible with the product stage of the control system.
Reaction: PLC Stop
Remedy: Translate the user program using a suitable programming tool version and load in the control.
Program Con-
tinuation:
Switch control OFF - ON.
400009 Computing time overrun at PLC level: [String] network [No.]
Definitions: [String] : module type
[No.] : network number
Check user program of the corresponding network displayed.
Reaction: PLC Stop
Remedy: Change user program
Program Con-
tinuation:
Switch control OFF - ON.
400010 Arithmetic error in user program: [Type] [String] network [No.]
Definitions: Check user program in the specified network.
Type 1:Division by zero using fixed point arithmetic
Type 2:Floating point (real number) arithmetic
[String]type number, module ID
[No.]network number
Reaction: PLC Stop
Remedy: Change user program.
Program Con-
tinuation:
Switch control OFF - ON.
400011 Permitted number of sub-program levels exceeded: [String] network
[no.]
Definitions: [String]module ID
[No.] :network number
Check user program in the specified network.
Reaction: PLC Stop
Remedy: Change user program.
Program Con-
tinuation:
Switch control OFF - ON.
400013 PLC user program is incorrect
Definitions: The PLC user program in the control is incorrect or is not available.
Reaction: PLC Stop
Remedy: Reload PLC user program.
Program Con-
tinuation:
Switch control OFF - ON.
400014 PROFIBUS DP: power up interrupted, type 1 - 4
Definitions: Type 1:PROFIBUS DP power up interrupted
Type 2:Software versions of NC – PLC do not match
Type 3:Number of slots per function exceeded
Type 4:PROFIBUS DP server not ready
Reaction: PLC Stop
Remedy: Types 1 to 3:Report error to Siemens
Type 4:802D – Check and/or replace PCU hardware and/or check MD 11240
Program Con-
tinuation:
Switch control OFF - ON.
Przeglądanie stron 338
1 2 ... 334 335 336 337 338 339 340 341 342 343 344 ... 391 392

Komentarze do niniejszej Instrukcji