Overview of alarms 06/2007
NCK alarms/ISO alarms
2-18
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
- $MC_AXCONF_MACHAX_USED[4] = 2
- $MC_AXCONF_MACHAX_USED[5] = 0
- $MC_AXCONF_MACHAX_USED[6] = 1
- $MC_AXCONF_MACHAX_USED[7] = 0
This channel uses the five machine axes 1, 2, 3, 8, 7, i.e. it has 5 active channel axes.
Reaction: NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Modify $MC_AXCONF_MACHAX_USED.
Program Con-
tinuation:
Switch control OFF - ON.
4010 Invalid identifier used in machine data %1[%2]
Parameters: %1 = string: MD identifier
%2 = index: MD array index
Definitions: When defining names for machine axes, one of the following syntax rules for the identifier to be
entered has been violated:
1.The identifier must be an NC address letter (A, B, C, I, J, K, U, V, W, X, Y, Z), possibly with a numer-
ical extension.
2.The identifier must begin with 2 arbitrary capital letters but not with $ (reserved).
3.The identifier must not be a vocabulary word of the NC language (e.g. SPOS).
Reaction: NC not ready.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department.
Enter the identifier for user-defined names with correct syntax in the displayed MD.
Machine axes:MD 10000 AXCONF_MACHAX_NAME_TAB
Program Con-
tinuation:
Switch control OFF - ON.
4011 Channel %1 invalid identifier used in machine data %2[%3]
Parameters: %1 = channel number
%2 = string: MD identifier
%3 = index: MD array index
Definitions: When defining names in the channel-specific tables for geometry axes and channel axes, one of the
following syntax rules for the identifier to be entered has been violated:
The identifier must be an NC address letter (A, B, C, I, J, K, U, V, W, X, Y, Z), possibly with a numerical
extension.
The identifier must begin with 2 arbitrary capital letters but not with $ (reserved for system variable).
The identifier must not be a vocabulary word of the NC language (e.g. SPOS).
Reaction: NC not ready.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department.
Enter the identifier for user-defined names with correct syntax in the displayed MD
Geometry axes:MD 20060 AXCONF_GEOAX_ASSIGN_TAB
Channel axes:MD 10000 AXCONF_MACHAX_NAME_TAB
Program Con-
tinuation:
Switch control OFF - ON.