List of action numbers 06/2007
3-354
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
No. 69, PROGESTON
No. 70, PROGESTOFF
No. 71, STOPATIPOBUFFER_ISEMPTY_ALARM
No. 72, STOPATIPOBUF_EMPTY_ALARM_REORG
No. 73, CONDITIONAL_STOPATEND
Explanation Activate program test (VDI signal: Program test).
Cause 1. Tool management is active
2. The NCK channel is in a state other than "ready"
Remedy − Backing up tool data
− Abort the program or process with the Reset key or
− wait for end of program
Explanation Deactivate program test (VDI signal: Program test).
Cause The NCK channel is in a state other than "ready"
Remedy − Abort the program or process with the Reset key or
− wait for end of program
Explanation Stop at the end of block preparation (alarm)
Cause -
Remedy -
Explanation Stop at the end of block preparation with subsequent reorganization of block processing
(alarm)
Cause Nesting depth too great
Remedy − Wait until the preceding ASUB is complete or
− Abort program
Explanation Conditional stop at block end. If, after continuation by means of an NC Start, there is still
a reason to stop "Stop at block end", the program stops again.
Cause -
Remedy -