NCK alarms/ISO alarms
06/2007 Overview of alarms
2-193
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
16946 Channel %1 start via START is not allowed
Parameters: %1 = Channel ID
Definitions: This alarm is active with "Group Serupro" only. _Group Serupro" is activated by means of
"$MC_SERUPRO_MODE BIT2" and enables the retrace support of entire channel groups during
block search.
The machine data $MC_DISABLE_PLC_START specifies which channel is generally started from the
PLC and which channel is only allowed to be started from another channel via the START part pro-
gram command.
This alarm occurs if the channel was started via the START part programm command and
$MC_DISABLE_PLC_START==FALSE was set.
Reaction: Alarm display.
Remedy: Modify $MC_DISABLE_PLC_START of switch off "Group Serupro" (see $MC_SERUPRO_MODE).
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
16947 Channel %1 start via PLC is not allowed
Parameters: %1 = Channel ID
Definitions: This alarm is active with "Group Serupro" only. _Group Serupro" is activated by means of
"$MC_SERUPRO_MODE BIT2" and enables the retrace support of entire channel groups during
block search.
The machine data $MC_DISABLE_PLC_START specifies which channel is generally started from the
PLC and which channel is only allowed to be started from another channel via the START part pro-
gram command.
This alarm occurs if the channel was started via the PLC and $MC_DISABLE_PLC_START==TRUE
was set.
Reaction: Alarm display.
Remedy: Modify $MC_DISABLE_PLC_START of switch off "Group Serupro" (see $MC_SERUPRO_MODE).
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
16948 Channel %1 dependent channel %2 still active
Parameters: %1 = Channel ID
%2 = Channel ID
Definitions: This alarm is active with "Group Serupro" only. _Group Serupro" is activated by means of
"$MC_SERUPRO_MODE BIT2" and enables the retrace support of entire channel groups during
block search.
A _dependent channel_ is a channel that had indirectly been started by the currently active channel.
The currently active channel was started via PLC.
This channel m_u_s_t be terminated (i.e. reached M30) before the current channel is terminated.
This alarm occurs if the currently active channel is terminated before the dependent channel.
Reaction: Alarm display.
Remedy: Switch off "Group Serupro" (see $MC_SERUPRO_MODE) or install WAITE.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
16949 Correspondence between marker of channel %1 and channel %2 is
invalid.
Parameters: %1 = Channel ID
%2 = Channel ID
Definitions: This channel defines a WAIT marker with other channels, which on their part have no correspondence
with this wait marker.
This channel's WAIT marker has no explicit counterpart in the other channel; i.e. the channels do not
mutually wait.