Cycle alarms
06/2007 Overview of alarms
2-291
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
61224 Channel %1 Block %2: Retract path too small
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The retract path must not be less than zero.
Alarm triggered by following cycles: E_MI_CON, F_MI_CON.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Enter a greater value for the retract path.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61225 Channel %1 block %2: Swivel data record unknown
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: An attempt was made to access a swivel data block which has not been defined.
Alarm triggered by following cycles: E_TCARR, F_TCARR.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Select another swivel data block or define a new swivel data block.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61226 Channel %1 block %2: Inclinable head cannot be exchanged
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The parameter "Swivel data block" is set to "No". In spite of this, an attempt has been made to change
the swivel head.
Alarm triggered by following functions: E_TCARR, F_TCARR.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Set the parameter "Swivel data block" in the start-up screen "Rotary axes" to "Automatic" or "Manual".
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61231 Channel %1 block %2: ShopMill program %4 not executable, as not
tested by ShopMill
Parameters: %1 = Channel number
%2 = Block number, label
%4 = Program name
Definitions: Before a ShopMill program can be executed, it has to be tested by ShopMill.
Alarm triggered by following cycle: E_HEAD.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: The program has to be simulated first in ShopMill or loaded into the operating mode "Machine auto"
by ShopMill.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61232 Channel %1 block %2: Impossible to load magazine tool
Parameters: %1 = Channel number
%2 = Block number, label