Cycle alarms
06/2007 Overview of alarms
2-319
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
61804 Channel %1 block %2: Progr. position exceeds reference point
Parameters:
Definitions: Source (cycle):
CYCLE328
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: The programmed intermediate position or actual position is behind the reference point.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61805 Channel %1 block %2: Value programmed absolute and incremental
Parameters:
Definitions: Source (cycle):
CYCLE328
CYCLE371T to CYCLE374T, CYCLE376T,
CYCLE383T, CYCLE384T
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: The programmed intermediate position is both absolutely and incrementally programmed.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61806 Channel %1 block %2: Wrong axis assignment
Parameters:
Definitions: Source (cycle):
CYCLE328
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: The axis-assignment sequence is wrong.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61807 Channel %1 block %2: Wrong spindle direction programmed (active)
Parameters:
Definitions: Source (cycle):
CYCLE384M
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: The programmed spindle direction contradicts the spindle direction planned for the cycle.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61808 Channel %1 block %2: Final drilling depth or single drilling depth
missing
Parameters:
Definitions: Source (cycle):
CYCLE381M, CYCLE383M, CYCLE384M,
CYCLE387M,
CYCLE383T to CYCLE385T