Overview of alarms 06/2007
NCK alarms/ISO alarms
2-156
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
Remedy: Please inform the authorized personnel/service department. Correct INI file or correct MD and create
new INI file (via "upload").
Program Con-
tinuation:
Switch control OFF - ON.
15186 Channel %1 %2 errors in GUD, macro or INI file
Parameters: %1 = Channel number
%2 = Number of detected errors
Definitions: %2 errors were found when processing GUD/macro definition files (DEF files) or initialization files (INI
files)
Alarm 15180 has already informed about the corresponding file.
Prior to that the errors shown were reported by error-specific alarms, e.g. 12080 "syntax error".
Reaction: NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Modify definition file or initialization file
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
15187 Channel %1 error during execution of PROGEVENT file %2.
Parameters: %1 = Channel number
%2 = PROGEVENT file name
Definitions: An error has occurred on executing PROGEVENT.
With alarm 15187, the name of the program that was started as PROGEVENT
is displayed. Alarm 15187 is displayed together
with the alarm that describes the error cause. Alarm 15187 is also output
when the alarm occurs in a subroutine started from PROGEVENT.
Reaction: Interface signals are set.
Alarm display.
Remedy: Correct the PROGEVENT file (subroutine).
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
15188 Channel %1 error during execution of ASUB file %2.
Parameters: %1 = Channel number
%2 = ASUB file name
Definitions: An error has occurred on executing an ASUB.
Alarm 15188 displays the name of the program that was started
as ASUB. Alarm 15188 is output together with the alarm that
describes the error cause. Alarm 15188 is also output when
the alarm occurs in a subroutine started from the ASUB.
Reaction: Interface signals are set.
Alarm display.
Remedy: Correct the ASUB file (subroutine).
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
15190 Channel %1 block %2 not enough free memory for subroutine call
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The following deadlock has been found in the interpreter:
Memory is needed for calling a subroutine. The module memory is, however, empty and there is no
prospect of module memory becoming free again by executing the preprocessing/main run queue,
because this queue is empty.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Program the STOPRE preprocessing stop before the subroutine call.