Overview of alarms 06/2007
NCK alarms/ISO alarms
2-26
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
4114 Error in DP cycle of SDB-Type-2000
Parameters: %1 = String (new PLC cycle)
Definitions: The DP cycle in the SDB contains an error and cannot be set.
The default value of MD 10050 SYSCLOCK_CYCLE_TIME is set.
Reaction: Alarm display.
Remedy: Correct the SDB.
Program Con-
tinuation:
Switch control OFF - ON.
4115 Time ratio communication to Ipo changed to %1
Parameters: %1 = String (new PLC cycle time)
Definitions: The value of the machine data 10072 has been adapted. This can only occur, if the value of the
machine data is smaller than one and the time thus calculated is no multiple of the position control
cycle.
Reaction: Alarm display.
Remedy: The machine data $MN_COM_IPO_TIME_RATIO has been adapted. Please check to ensure that the
calculated value is correct.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4150 Channel %1 invalid M function subprogram call configured
Parameters:
Definitions: In MD MD 10715 M_NO_FCT_CYCLE, an M function that is occupied by the system has been spec-
ified for the configuration of the subprogram call and cannot be replaced by a subprogram call (M0 to
M5, M17, M19, M30, M40 to M45, M70). When external language is active, M96 to M99 are also
blocked
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Configure an M function which is not used by the system (M0 to M5, M17, M19, M30, M40 to M45 and
M70) in MD 10715 M_NO_FCT_CYCLE.
Program Con-
tinuation:
Switch control OFF - ON.
4152 Illegal configuration of the 'Block display with absolute values' function
Definitions: The "Block display with absolute values" function has been illegally parameterized:
- An illegal block length has been set with MD 28400 MM_ABSBLOCK:
While ramping up, the machine data will be checked for the following value range:
0, 1, 128 to 512
- An invalid display range has been set with MD 28402 MM_ABSBLOCK_BUFFER_CONF[]. While
ramping up, the machine data will be checked for the following upper and lower limits:
0 <= $MC_MM_ABSBLOCK_BUFFER_CONF[0] <= 8
0 <= $MC_MM_ABSBLOCK_BUFFER_CONF[1] <= (MD 28060 MM_IPO_BUFFER_SIZE + MD
28070 MM_NUM_BLOCKS_IN_PREP).
Alarm 4152 is issued if the limits are violated.
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Configure block length/display range within the permissible limits.
Program Con-
tinuation:
Switch control OFF - ON.