14761 Channel %1 block %2 motion synchronous action: DELDTG function not
allowed with active tool radius compensation
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Rapid delete distance-to-go for synchronous actions is not allowed with DELDTG when tool radius
compensation is active.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Deactivate tool radius compensation before performing rapid delete distance-to-go and then reselect
or
as of SW 4.3: "Delete distance-to-go without preparation".
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14762 Channel %1 block %2 too many PLC variables programmed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The number of programmed PLC-variable auxiliary functions has exceeded the maximum permitted
number. The number is set in MD 28150 MM_NUM_VDIVAR_ELEMENTS.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Modify part program or machine data.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
14770 Channel %1 block %2 auxiliary function programmed incorrectly
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The permissible number of programmed auxiliary functions per NC block has been exceeded or more
than one auxiliary function of the same auxiliary function group has been programmed (M and S func-
tion).
In the user-defined auxiliary functions, the maximum number of auxiliary functions per group in the NC
system settings has been defined for all auxiliary functions by means of the MD 11100
AUXFU_MAXNUM_GROUP_ASSIGN (default: 1).
For each user-defined auxiliary function to be assigned to a group, the assignment is made using 4
machine data items.
MD 22010 AUXFU_ASSIGN_TYPE: Auxiliary function type, e.g. M
MD 22000 AUXFU_ASSIGN_GROUP: Required group
MD 22020 AUXFU_ASSIGN_EXTENSION:Possibly required extension
MD 22030 AUXFU_ASSIGN_VALUE: Function value
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Correct the part program - max. 16 auxiliary functions, max. 5 M functions per NC block, max. 1 aux-
iliary function per group.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.