NCK alarms/ISO alarms
06/2007 Overview of alarms
2-69
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
10748 Channel %1 block %2 illegal retract plane with WAB
Parameters: %1 = channel number
%2 = block number, label
Definitions: By means of DISRP a position of the retraction plane has been programmed which is not situated
between the safety distance (DISCL) and the starting point (during approach) and/or end point (during
retraction) of the SAR movement.
Reaction: Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy: Modify part program
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
10750 Channel %1 block %2 tool radius compensation activated without tool
number
Parameters: %1 = channel number
%2 = block number, label
Definitions: A tool T... must be selected so that the control can make allowance for the associated compensation
values.
A correction data block (D1) containing the correction values (parameter P1 - P25) is automatically
assigned to each tool (T number). Up to 9 correction data blocks can be assigned to a tool by speci-
fying the required data block with the D number (D1 - D9).
The tool radius compensation (TRC) is allowed for if function G41 or G42 is programmed. The correc-
tion values are contained in parameter P6 (geometry value) and P15 (wear value) of the active cor-
rection data block Dx.
Reaction: Correction block is reorganized.
Interpreter stop
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy: Before calling the TRC with G41/G42, program a tool number under the address T...
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
10751 Channel %1 block %2 danger of collision due to tool radius
compensation
Parameters: %1 = channel number
%2 = block number, label
Definitions: The "Bottleneck detection" (calculation of intersection for the following compensated traversing
blocks) has not been able to calculate a point of intersection for the reviewed number of traversing
blocks. So it may be that one of the equidistant paths violates the workpiece contour.
Reaction: Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy: Check the part program and modify the programming if possible such that inside corners with smaller
paths than the correction value are avoided. (Outside corners are not critical, since the equidistants
are extended or added to always obtain an intersection point).
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.