06/2007 List of action numbers
3-343
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
No. 8, OVERSTOREON
No. 9, OVERSTOREOFF
No. 10, INTERRUPT
No. 11, INTERRUPTFASTLIFTOFF
Explanation Activate overstore (PI command).
Cause -
Remedy -
Explanation Activate overstore (PI command).
Cause -
Remedy -
Explanation Perform user interrupt "ASUB" (VDI signal: Digital-analog interface, ASUB interface).
Cause 1. The channel is active due to block search or loading machine data
2. The channel has been stopped and the asynchronous subroutine
"ASUP_START_MASK" must be started and the current block cannot be reorga-
nized.
3. Digitizing has been selected.
4. Reference point approach has not been performed yet.
5. The active block, after which deceleration takes place, cannot be reorganized (occurs
when deceleration takes place over several blocks).
Remedy Wait until the block search or loading MD is completed, or abort program (Reset
key)
Activate a block change until the NC block can be reorganized.
Deactivate digitizing
Perform reference point approach or ignore this state via the MD
"ASUP_START_MASK".
Abort program
Explanation Perform "ASUB" user interrupt with rapid retraction (VDI signal: Digital-analog interface).
Cause See No. 10
Remedy -